THERMAL SIMULATIONS, COMPARE COOLING STRUCTURES FOR ASYNCHRONOUS SERVOMOTOR

107 views

Authors

Keywords:

Servomotor; Thermal model; Dissipation design; Thermal calculation; Motor optimization.

Abstract

This paper presents thermal simulations and compares different cooling structures of an asynchronous servomotor. Thank to the advantage of almost instantaneous calculation speed, the design process can quickly analyze the thermal changes in motor components. The Motor-CAD software is used to select parameters related to the heat generation in the optimal design of the electric machine. The application of thermal-electromagnetic simulation in the design process reduces the requirements for prototype manufacturing and testing, thus reducing the research time and costs. Based on the results of thermal analysis and the threshold temperature limit of the components in the machine, this paper has both objectives: considering the optimal parameters and selecting the cooling architecture to minimize the mass or the production cost, while maximizing the peak torque of the servomotor.

References

[1]. Aldo Boglietti, Andrea Cavagnino, David Staton, Martin Shanel, Markus Mueller, and Carlos Mejuto, “Evolution and modern approaches for thermal analysis of electrical machines”, IEEE Transactions on Industrial Electronics, Vol. 56, (2009), no. 3, pp. 871-882.

[2]. D. A. Staton, A. Cavagnino, “Convection Heat Transfer and Flow Calculations Suitable for Electric Machines Thermal Models”, IEEE Transactions on Industrial Electronics, Vol. 55, No. 10, (2008), pp. 3509-3516.

[3]. A. Boglietti, A. Cavagnino, “Analysis of the Endwinding Cooling Effects in TEFC Induction Motors”, IEEE Transactions on Industry Applications, Vol. 43, No. 5, (2007), pp.1214 – 1222.

[4]. Arbab, N., Wang, W., Lin, C., Hearron, J.,Fahimi, B. “Thermal modeling and analysis of a double-stator switched reluctance motor”, IEEE Transactions on Energy Conversion, Vol. 30, No 3 (2015), pp.12 09-1217.

[5]. D. Staton, S. J. Pickering, and D. Lampard, “Recent advancement in the thermal design of electric motors”, in Proc. SMMA—Fall Tech. Conf., Durham, NC, (2001), pp 3–5.

[6]. A. Boglietti, A. Cavagnino, M. Lazzari, and M. Pastorelli, “A simplified thermal model for variable-speed self-cooled industrial induction motor”, IEEE Transactions on Industrial Application, Vol. 39, no. 4, (2002), pp. 723–730.

[7]. Staton, D.A., Boglietti, A., Cavagnino, A, “Solving the More Difficult Aspects of Electric Motor Thermal Analysis in Small and Medium Size Industrial Induction Motors”, IEEE Transactions on Energy Conversion, Vol 20, Issue 3, (2005), pp. 620 – 628.

[8]. M. Kasprzak, J. W. Jiang, B. Bilgin, and A. Emadi, “Thermal analysis of a three-phase 24/16 switched reluctance machine used in HEVs,” IEEE Energy Conversion Congress and Exposition, Proceedings. (2016), pp.1-7.

[9]. Dave Stoton, Livio Susnjic, “Induction Motors Thermal Analysis”, Strojarstvo Vol 51, No. 6, (2009), pp. 623-631.

[10]. M. Roffi, F. J. T. E. Ferreira and A. T. De Almeida, “Comparison of different cooling fan designs for electric motors”, 2017 IEEE International Electric Machines and Drives Conference (IEMDC), Miami, FL, 2017, pp. 1-7.

Published

05-02-2021

How to Cite

Bắc. “THERMAL SIMULATIONS, COMPARE COOLING STRUCTURES FOR ASYNCHRONOUS SERVOMOTOR”. Journal of Military Science and Technology, no. 71, Feb. 2021, pp. 63-70, https://en.jmst.info/index.php/jmst/article/view/99.

Issue

Section

Research Articles

Most read articles by the same author(s)