Fabrication of non-dispersive infrared sensor (NDIR) for detecting CO2 in indoor with low-level concentration towards human health safety applications

335 views

Authors

  • Trinh My Anh Trường THPT chuyên Hùng Vương Gia Lai
  • Dang Le Gia Han Trường THPT chuyên Hùng Vương Gia Lai
  • Mai Ngoc Linh Trường THPT chuyên Hùng Vương Gia Lai
  • Pham Duy Tan Institute of Materials Science, Vietnam Academy of Science and Technology
  • Bui Xuan Khuyen (Corresponding Author) Institute of Materials Science, Vietnam Academy of Science and Technology
  • Ho Truong Giang Institute of Materials Science, Vietnam Academy of Science and Technology

DOI:

https://doi.org/10.54939/1859-1043.j.mst.77.2022.120-127

Keywords:

Cảm biến khí NDIR; Ảnh hưởng CO2 tới sức khỏe con người; CO2 vùng nồng độ thấp không khí trong nhà.

Abstract

Carbon dioxide (CO2) is known as a gas of global climate change and global warming as well as impacts on human health. Recently, scientific literature and documents have been shown that exposure at the CO2 low-level concentration (~5000 ppm) for a long-time can affect human health and psychomotor performance. It is more serious in modern life when humans are usually in indoor environments with low ventilation rates such as school-rooms, office-rooms, buildings, etc. In indoor environments, the low-level CO2 concentrations can be easy to obtain due to release from the processes like human metabolism, cooking, and fuel combustion. On the other hand, it is more dangerous because carbon dioxide is a colorless, odorless, and tasteless gas that is undetectable to the human senses and causes long-term and silent effects on human health. It can be related to respiratory, cardiovascular, kidney, bone, neurological, cognitive, and autism diseases, particularly in children and people with weak-physical conditions. In this work, the infrared absorption gas sensor was fabricated for detecting CO2 in the range of low-level concentration (0 ¸ 10.000 ppm), towards applications in monitoring and conditioning CO2 concentration in indoor environments. The configuration of the sensor is a non-dispersive infrared (NDIR) structure with two infrared detectors. A porous ceramic tube was used to gas self-diffusion from the environment into the gas-sampling chamber of the sensor. The NDIR sensor showed good performance with a resolution of 2 ppm, limitation of detection (LoD) of 0.5 ppm, and standard deviation of 10 ppm. 

References

[1]. https://www.vinmec.com/vi/tin-tuc/thong-tin-suc-khoe/o-nhiem-khong-khi-anh-huong-den-suc-khoe-con-nguoi-nao/

[2]. W.M. Alberts, "Indoor air pollution: NO, NO2, CO, and CO2", The Journal of Allergy and Clinical Immunology, 94 (1994) 289-295.

[3]. Kenichi Azuma, Naoki Kagi, U. Yanagi, Haruki Osawa, "Effects of low-level inhalation exposure to carbon dioxide in indoor environments: A short review on human health and psychomotor performance", Environment International, 121 (2018) 51-56.

[4]. https://baotainguyenmoitruong.vn/canh-bao-nong-do-co2-trong-nha-co-the-la-moi-nguy-hai-cho-suc-khoe-289251.html.

[5]. U. Satish, M. J. Mendell, K. Shekhar, T. Hotchi, D. Sullivan, S. Streufert, W. J. Fisk, "Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 concentrations on human decision-making performance", Environmental Health Perspectives, 120 (2012) 1671-1677.

[6]. H. Maula, V. Hongisto, V. Naatula, "The effect of low ventilation rate with elevated bioeffuent concentration on work performance, perceived indoor air quality, and health symptoms", Indoor Air 27 (2017) 1141-1153.

[7]. S. Petersen, K.L. Jensen, A.L Pedersen, H.S. Rasmussen, "The effect of increased classroom ventilation rate indicated by reduced CO2 concentration on the performance of schoolwork by children", Indoor Air 26 (2016) 366-379.

[8]. Jane Hodgkinson, Ralph P Tatam, "Optical gas sensing: a review", Measurement Science and Technology, 24 (2013) 012004.

[9]. Robert Lee, Walt Kester, "Complete Gas Sensor Circuit Using Nondispersive Infrared (NDIR)", Analog Dialogue 50-10, (2016)

[10]. Báo cáo đề tài "Nghiên cứu, thiết kế, chế tạo các cảm biến để xây dựng hệ thống thiết bị đo nồng độ khí thải và điều khiển quá trình đốt cháy nhiên liệu", mã số KC05.13/16-20, (2021)

[11]. Nguyen Van Hieu, Nguyen Duc Khoang, Do Dang Trung, Le Duc Toan, Nguyen Van Duy, Nguyen Duc Hoa, "Comparative study on CO2 and CO sensing performance of LaOCl-coated ZnO nanowires", J Hazardous Materials 244-245, 209-216 (2013).

[12]. P. Romppainen, V. Lantto, "Design and construction of an experimental setup for semiconductor gas sensor studies", Report S: Department of Electrical Engineering, University of Oulu, Oulu, Filand, 93 (1987)

[13]. https://labincubators.net/blogs/blog/thermal-conductivity-versus-infrared-co2-sensors.

[14]. Igor Cretescu, Doina Lutic, Liliana Rosemarie Manea, "Electrochemical sensors for monitoring of Indoor and outdoor air pollution", http://dxdoiorg/105772/intechopen68512, (2017).

Published

25-02-2022

How to Cite

Trịnh Mỹ Anh, Đặng Lê Gia Hân, Mai Ngọc Linh, Phạm Duy Tân, X. K. Bùi, and Hồ Trường Giang. “Fabrication of Non-Dispersive Infrared Sensor (NDIR) for Detecting CO2 in Indoor With Low-Level Concentration towards Human Health Safety Applications”. Journal of Military Science and Technology, no. 77, Feb. 2022, pp. 120-7, doi:10.54939/1859-1043.j.mst.77.2022.120-127.

Issue

Section

Research Articles

Most read articles by the same author(s)